    CONSTRUCTION:

    • Conductor : High immaculateness electrolytic class brilliant tempered adaptable grouped bare, copper conduit as per global guidelines like IS-8130, BS-6360, IEC-228 & VDE-0295.
    • Insulation : Specially made dielectric class PVC Compound impenetrable to oils, grease, water and so forth.
    • Sheath    : Bendable high friction and inner sheath safe extreme and adaptable PVC Compound.
    • Standard Colors:Grey, Red, Blue, Black, other colors as per requirements.
    • Application:Use in high ambient temperatures
    • Standards:IS 694, BS 6500, IEC 60227, CEI 20-20, VDE 0281, SABS 1574, AS 3191, AS/NZS 5000.1, HD 21.1, NF C 32-201, French Standard 32-102-16
    • Working Voltage Uo/U:450/ 750 V, 600/ 1000 V,  650/1100 V
    • Test Voltage:3000 V
    • Temperature range:-150oC to 70oC




    2 & 3 Conductor without Ground *  THW  *   UL 83 * 600 V

    AWG size  & Number of conductors 

    AWG/No.

    Nominal Cable dimensions


    inch x inch

    Max. conductor resistance at 200C

    ohm/1000 feet

    Current carrying capacity at 300 C


    amps.

    14/20.370 x0.2322.52520
    12/20.433x0.2641.62825
    10/20.488x0.2950.99835
    14/30.512 x0.2322.52520
    12/30.606x0.2641.62825
    10/30.689x0.2950.99835
    8/30.878x0.3660.628250
    6/31.035x0.4250.395165
    4/31.268x0.5160.248585
    2/31.437x0.5790.1563115
    1/0-31.752x0.7010.098150
    2/0-32.008x0.7680.0729175
    3/0-32.315x0.8860.0618200
     
    2 & 3 Conductor with Ground *  THW  *   UL 83   *  600 V

    Number of cores x cross-section


    no. x awg

    Outer dimensions



    mm x mm

    Max. conductor resistance at 200C

    ohm/1000 feet

    Current carrying capacity at 300 C


    amps.

    14/2 W/14 Gr.0.512 x0.2322.52520
    12/2 W/12 Gr.0.606x0.2641.62825
    10/2 W/10 Gr.0.689x0.2950.99835
    8/2 W/10 Gr.0.819x0.3660.628250
    14/3 W/14 Gr.0.650x0.2322.52520
    12/3 W/12 Gr.0.776x0.2641.62825
    10/3 W/10 Gr.0.894x0.2950.99835
    8/3 W/10 Gr.1.075x0.3660.628250
    6/3 W/10 Gr.1.295x0.4330.395165
    4/3 W/8 Gr.1.535x0.5200.248585
    2/3 W/8 Gr.1.713x0.5790.1563115
    1/0-3 W/6 Gr.2.185x0.7480.098150
    2/0-3 W/6 Gr.2.433x0.8270.0729175
    3/0-3 W/6 Gr.2.559x0.8820.0618200
     
    Note:
    Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295.
     
     

      Trade Information
      • Mundra & Nhava Sheva
      • Cash in Advance (CID), Cheque, Letter of Credit at Sight (Sight L/C)
      • 2 Lacs meters Per Day
      • Can be scheduled Days
      • Yes
      • Free samples are available
      • In a sea worthy wooden reels.
      • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
      • All India
      • UL, Ce, IS, etc.